New Instrument Combines Ultrafast High-Pressure Freezing with Integrated Light Stimulation

By LabMedica International staff writers
Posted on 02 Sep 2015
Print article
The EM ICE high-pressure freezer
The EM ICE high-pressure freezer (Photo courtesy of Leica Biosystems - Diagnostics Danaher)
A new generation high-pressure freezer with fully integrated millisecond light stimulation option is now available to biotech and other life sciences researchers.

High-pressure freezing is currently the only method for preserving aqueous samples in their close-to-native state at nanometer resolution. A new instrument, the Leica Microsystems (Wetzlar, Germany) EM ICE not only preserves samples at the temperature of liquid nitrogen without introducing structural alterations, but it enables researchers to design novel experiments, since the Leica EM ICE offers the combination of high pressure freezing and light stimulation.

Synchronizing light stimulation and high-pressure freezing enables visualization of highly dynamic processes or the structural changes of photosensitive samples at a nanometer resolution and millisecond precision.

The combination of two powerful techniques: optogenetics and high-pressure freezing now makes it possible to visualize dynamic cellular activity with temporal resolution of five milliseconds. By coupling a flash of light with high-pressure freezing, such processes as vesicle recycling at the synapses can now be imaged by electron microscopy.

The EM ICE offers five different wavelengths for light stimulation and can freeze up to nine samples consecutively with its new sample storage system. Samples are frozen within one second of having been placed in the specimen carrier and brought to liquid nitrogen temperatures (-195.7 degrees Celsius, 77.45 K) at which they will be stored until further processed.

An inbuilt connection for LED light modules allows the Leica EM ICE to perform light stimulation at wave-lengths that generate blue, UV, green, red, or amber light. Integrated light stimulation facilitates precise correlation between the light stimulus and the moment of freezing.

Dr. Cveta Tomova, product manager at Leica Microsystems said, "The Leica EM ICE is a powerful tool that can bring to light new discoveries and even help understand life-sustaining processes. It is the only instrument capable of synchronizing high pressure freezing and light stimulation with a millisecond precision. The platform brings together light, time, and sample preservation on a new level. This is a combination of quality and technological innovation, designed to assist researchers in achieving scientific breakthroughs. High pressure freezing combined with light stimulation can be applied to any light-sensitive compound such as lotions, photoactivatable composite materials, proteins, and various biological samples. It can push further our understanding of highly dynamic processes, such as neurotransmission at the synapse."

Related Links:

Leica Microsystems


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
One Step HbA1c Measuring System
GREENCARE A1c
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Magnetic Bead Separation Modules
MAG and HEATMAG
Read the full article by registering today, it's FREE! It's Free!
Register now for FREE to LabMedica.com and get complete access to news and events that shape the world of Clinical Laboratory Medicine.
  • Free digital version edition of LabMedica International sent by email on regular basis
  • Free print version of LabMedica International magazine (available only outside USA and Canada).
  • Free and unlimited access to back issues of LabMedica International in digital format
  • Free LabMedica International Newsletter sent every week containing the latest news
  • Free breaking news sent via email
  • Free access to Events Calendar
  • Free access to LinkXpress new product services
  • REGISTRATION IS FREE AND EASY!
Click here to Register








Channels

Clinical Chemistry

view channel
Image: Reaching speeds up to 6,000 RPM, this centrifuge forms the basis for a new type of inexpensive, POC biomedical test (Photo courtesy of Duke University)

POC Biomedical Test Spins Water Droplet Using Sound Waves for Cancer Detection

Exosomes, tiny cellular bioparticles carrying a specific set of proteins, lipids, and genetic materials, play a crucial role in cell communication and hold promise for non-invasive diagnostics.... Read more

Molecular Diagnostics

view channel
Image: MOF materials efficiently enrich cfDNA and cfRNA in blood through simple operational process (Photo courtesy of Science China Press)

Blood Circulating Nucleic Acid Enrichment Technique Enables Non-Invasive Liver Cancer Diagnosis

The ability to diagnose diseases early can significantly enhance the effectiveness of clinical treatments and improve survival rates. One promising approach for non-invasive early diagnosis is the use... Read more

Hematology

view channel
Image: The low-cost portable device rapidly identifies chemotherapy patients at risk of sepsis (Photo courtesy of 52North Health)

POC Finger-Prick Blood Test Determines Risk of Neutropenic Sepsis in Patients Undergoing Chemotherapy

Neutropenia, a decrease in neutrophils (a type of white blood cell crucial for fighting infections), is a frequent side effect of certain cancer treatments. This condition elevates the risk of infections,... Read more

Pathology

view channel
Image: The OvaCis Rapid Test discriminates benign from malignant epithelial ovarian cysts (Photo courtesy of INEX)

Intra-Operative POC Device Distinguishes Between Benign and Malignant Ovarian Cysts within 15 Minutes

Ovarian cysts represent a significant health issue for women globally, with up to 10% experiencing this condition at some point in their lives. These cysts form when fluid collects within a thin membrane... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.