We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Compressed Ultrafast Photography Designed to Aid Scientific Research

By LabMedica International staff writers
Posted on 31 Dec 2014
Print article
Image: Washington University engineers have developed the world’s fastest receive-only 2-D camera that can capture events up to 100 billion frames per second (Photo courtesy of Washington University).
Image: Washington University engineers have developed the world’s fastest receive-only 2-D camera that can capture events up to 100 billion frames per second (Photo courtesy of Washington University).
Image: The CUP system configuration (Photo courtesy of Washington University).
Image: The CUP system configuration (Photo courtesy of Washington University).
A group of biomedical engineers has developed the world’s fastest receive-only, two-dimensional (2-D) camera, a device that can capture actions up to 100 billion frames per second. That is remarkably more rapid than any current receive-only ultrafast imaging techniques, which are limited by on-chip storage and electronic readout speed to operations of approximately 10 million frames per second.

The researchers, from Washington University in St. Louis (MO, USA), and led by Lihong Wang, PhD, a professor of biomedical engineering, using the technique, called compressed ultrafast photography (CUP), have made movies of the images they captured with single laser shots of four physical phenomena: laser pulse reflection, refraction, faster-than light propagation of what is called non-information, and photon racing in two media. The images are compelling, remarkable, and represent a new era scientific exploration.

The research was published in the December 4, 2014, issue of the journal Nature. “For the first time, humans can see light pulses on the fly,” Prof. Wang said. “Because this technique advances the imaging frame rate by orders of magnitude, we now enter a new regime to open up new visions. Each new technique, especially one of a quantum leap forward, is always followed a number of new discoveries. It’s our hope that CUP will enable new discoveries in science—ones that we can’t even anticipate yet.”

This camera does not look similar to a typical one; instead, it is a range of devices envisioned to work with high-powered microscopes and telescopes to capture dynamic natural and physical phenomena. Once the raw data are acquired, the actual images are formed on a personal computer (PC) with the technology known as computational imaging.

The development of the technology was funded by two grants from the US National Institutes of Health that support pioneering and potentially transformative approaches to major challenges in biomedical research. “This is an exciting advance and the type of groundbreaking work that these high-risk NIH [US National Institutes of Health; Bethesda, MD, USA] awards are designed to support,” said Richard Conroy, PhD, program director of optical imaging at the US National Institute of Biomedical Imaging and Bioengineering, part of the NIH. “These ultrafast cameras have the potential to greatly enhance our understanding of very fast biological interactions and chemical processes and allow us to build better models of complex, dynamical systems.”

An immediate application is in biomedicine. One of the movies shows a green excitation light pulsing toward fluorescent molecules on the right where the green converts to red, which is the fluorescence. By tracking this, the researchers can get a single shot assessment of the fluorescence lifetime, which can be used to detect diseases or reflect cellular environmental conditions such as pH or oxygen pressure.

Prof. Wang envisions applications in astronomy and forensics, where the advanced imaging frame rate could study the temporal activities of a supernova that occurred light years away, or monitor and forecast the movements of thousands of potentially hazardous pieces of “space junk,” refuse of old satellites and jettisoned space craft hurtling about at high speed in outer space. In the forensic field, CUP might be used in reproducing bullet pathways, which could once again open up the [President] Kennedy assassination conspiracy theories and revive a more accurate analysis of the strange physics of the “magic bullet.”

Prof. Wang and his collaborators essentially added components and used algorithms to complement an existing technology known as a streak camera, which measures the intensity variation in a pulse of light with time. While a streak camera is fast, it gives only a one-dimensional view, which “is not intuitive—much analogous to watching a horse race through a distant vertical slit,” Dr. Wang said. “We expanded the view into 2-D space, more like what we see in the real world.”

CUP photographs an object with a specialty camera lens, which takes the photons from the object on a path through a tube-like structure to a tiny apparatus called a digital micromirror device (DMD), smaller than a dime though hosting approximately 1 million micromirrors, each one just seven by seven micrometers squared. There, micromirrors are used to encode the image, then reflect the photons to a beam splitter which shoots the photons to the widened slit of a streak camera. The photons are converted to electrons, which are then sheared with the use of two electrodes, converting time to space. The electrodes apply a voltage that ramps from high to low, so the electrons will arrive at different times and land at different vertical positions. An instrument called a charge-coupled device (CCD) stores all the raw data. All of this occurs at the remarkable pace of 5 nanoseconds (one nanosecond is a billionth of a second).

Prof. Wang’s research with CUP pushes the dimensional limits of fundamental physics and also pushes the limits of deep imaging of biologic tissues, one of Dr. Wang’s research specialties. “Fluorescence is an important aspect of biological technologies,” he stated. “We can use CUP to image the lifetimes of various fluorophores, including fluorescent proteins, at light speed.”

For astronomers, CUP can be a transformative, according to Dr. Wang. “Combine CUP imaging with the Hubble telescope, and we will have both the sharpest spatial resolution of the Hubble and the highest temporal solution with CUP,” he said. “That combination is bound to discover new science.”

Related Links:

Washington University in St. Louis


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Plasma Control
Plasma Control Level 1

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Signs of multiple sclerosis show up in blood years before symptoms appear (Photo courtesy of vitstudio/Shutterstock)

Unique Autoantibody Signature to Help Diagnose Multiple Sclerosis Years before Symptom Onset

Autoimmune diseases such as multiple sclerosis (MS) are thought to occur partly due to unusual immune responses to common infections. Early MS symptoms, including dizziness, spasms, and fatigue, often... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: Exosomes can be a promising biomarker for cellular rejection after organ transplant (Photo courtesy of Nicolas Primola/Shutterstock)

Diagnostic Blood Test for Cellular Rejection after Organ Transplant Could Replace Surgical Biopsies

Transplanted organs constantly face the risk of being rejected by the recipient's immune system which differentiates self from non-self using T cells and B cells. T cells are commonly associated with acute... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: A new study has identified patterns that predict ovarian cancer relapse (Photo courtesy of Cedars-Sinai)

Spatial Tissue Analysis Identifies Patterns Associated With Ovarian Cancer Relapse

High-grade serous ovarian carcinoma is the most lethal type of ovarian cancer, and it poses significant detection challenges. Typically, patients initially respond to surgery and chemotherapy, but the... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.