Human Heart-on-a-Chip Cultures May Replace Animal Models for Drug Development and Safety Screening

By LabMedica International staff writers
Posted on 22 Mar 2015
Print article
Image: Wafers like the one shown here are used to create “organ-on-a-chip” devices to model human tissue (Photo courtesy of Dr. Anurag Mathur, University of California, Berkeley).
Image: Wafers like the one shown here are used to create “organ-on-a-chip” devices to model human tissue (Photo courtesy of Dr. Anurag Mathur, University of California, Berkeley).
Human heart cells growing in an easily monitored silicon chip culture system may one day replace animal-based model systems for drug development and safety screening.

Drug discovery and development have long been hampered by high failure rates attributed to the reliance on non-human animal models employed during safety and efficacy testing. A fundamental problem in this inefficient process is that non-human animal models cannot adequately represent human biology.

To circumvent the physiological differences inherent in animal model systems, investigators at the University of California, Berkeley (USA) developed a human tissue-based model system using heart cells derived from selectively manipulated human pluripotent stem cells. The cells were induced to grow in a silicon chip device that contained a three-dimensional culture scaffold that was comparable to the geometry and spacing of connective tissue fiber in a human heart. Heart cells were loaded into the chip in multiple layers aligned in a single direction. Microfluidic channels on either side of the growth area served as models for blood vessels, mimicking the exchange by diffusion of nutrients and drugs with human tissue.

Results published in the March 9, 2015, edition of the journal Scientific Reports revealed that within 24 hours after the heart cells were loaded onto the chip, they began beating on their own at a normal physiological rate of 55 to 80 beats per minute. The culture system was able to keep human induced pluripotent stem cell derived cardiac tissue viable and functional over a period of several weeks.

The system was tested by monitoring the reaction of the heart cells to four different cardiovascular drugs: isoproterenol, E-4031, verapamil, and metoprolol. Changes in the heart tissue’s beat rate were monitored to gauge the response to the compounds. The experiment was considered to be a success when—after half an hour of exposure to isoproterenol, a drug used to treat bradycardia—the heart tissue beat rate increased from 55 to 124 beats per minute.

The "heart-on-a-chip" project was sponsored in part by the [US] National Institutes of Health's Tissue Chip for Drug Screening Initiative, an interagency collaboration for the development of three-dimensional human tissue chips that model the structure and function of human organs.

“Ultimately, these chips could replace the use of animals to screen drugs for safety and efficacy,” said senior author Dr. Kevin E. Healy, professor of bioengineering at the University of California, Berkeley. “Using a well-designed model of a human organ could significantly cut the cost and time of bringing a new drug to market.”

Related Links:
University of California, Berkeley


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
Complement 3 (C3) Test
GPP-100 C3 Kit
Gold Member
Xylazine Immunoassay Test
Xylazine ELISA

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Molecular Diagnostics

view channel
Image: Liquid biopsy could detect and monitor aggressive small cell lung cancer (Photo courtesy of Shutterstock)

Blood-Based Test Detects and Monitors Aggressive Small Cell Lung Cancer

Small cell lung cancer (SCLC) is a highly aggressive type of cancer known for its ability to metastasize. The behavior of tumors is largely governed by which genes are turned on, or transcribed, irrespective... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: The groundbreaking treatment approach has shown promise in hard-to-treat cancers (Photo courtesy of 123RF)

Genetic Testing Combined With Personalized Drug Screening On Tumor Samples to Revolutionize Cancer Treatment

Cancer treatment typically adheres to a standard of care—established, statistically validated regimens that are effective for the majority of patients. However, the disease’s inherent variability means... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.