We use cookies to understand how you use our site and to improve your experience. This includes personalizing content and advertising. To learn more, click here. By continuing to use our site, you accept our use of cookies. Cookie Policy.

Features Partner Sites Information LinkXpress
Sign In
Advertise with Us
PURITAN MEDICAL

Download Mobile App




Novel Microreactor Enables Evaluation of Drug Toxicity on the Liver

By LabMedica International staff writers
Posted on 26 Aug 2015
Print article
Image: Liver-on-chip device and microscopic image of bionic liver (Photo courtesy of Dr. Yaakov Nahmias, The Hebrew University of Jerusalem).
Image: Liver-on-chip device and microscopic image of bionic liver (Photo courtesy of Dr. Yaakov Nahmias, The Hebrew University of Jerusalem).
A novel three-dimensional microreactor capable of maintaining metabolically active liver cells in vitro for over 28 days under stable oxygen gradients that mimic the in vivo microenvironment of the liver was used to determine why the painkiller acetaminophen (paracetamol) causes damage to this organ.

The liver tissue-based microreactor was the fruit of a project conducted by investigators at The Hebrew University of Jerusalem (Israel) and their colleagues at the Fraunhofer Institute for Cell Therapy and Immunology (Munich, Germany). The device was capable of maintaining the growth of liver cells under carefully controlled conditions for up to 28 days. Mitochondrial respiration was monitored using two-frequency phase modulation of phosphorescent microprobes embedded in the tissue. Phase modulation is focus independent and unaffected by cell death or migration.

The investigators reported in the June 4, 2015, online edition of the journal Archives of Toxicology that the device enabled the sensitive measurement of oxygen dynamics that revealed important information on the drug mechanism of action and transient subthreshold effects. Exposure to the widely used analgesic acetaminophen caused an immediate, reversible, dose-dependent loss of oxygen uptake followed by a slow, irreversible, dose-independent death. Transient loss of mitochondrial respiration was also detected below the threshold of acetaminophen toxicity.

It had been thought that liver toxicity was linked to acetaminophen's toxic byproduct NAPQI (N-acetyl-p-benzoquinone imine), which is normally produced only in small amounts and then almost immediately detoxified in the liver. However, under some conditions in which NAPQI is not effectively detoxified (usually in case of acetaminophen overdose), it causes severe damage to the liver. This becomes apparent three to four days after ingestion and may result in death from fulminant liver failure several days after the overdose. Results obtained with the liver bioreactor demonstrated the importance of tracing toxicity effects over time and suggested that NAPQI-independent targeting of mitochondrial complex III might be responsible for acetaminophen toxicity.

“The liver organs we created were less than a millimeter in diameter and survive for more than a month,” said senior author Dr. Yaakov Nahmias, professor of bioengineering at The Hebrew University of Jerusalem. “We realized that because we are building the organs ourselves, we are not limited to biology, and could introduce electronic and optical sensors to the tissue itself. Essentially we are building bionic organs on a chip. Because we placed sensors inside the tissue, we could detect small and fast changes in cellular respiration that nobody else could. Suddenly nothing we saw made sense.”

Related Links:

The Hebrew University of Jerusalem
Fraunhofer Institute for Cell Therapy and Immunology


Platinum Member
COVID-19 Rapid Test
OSOM COVID-19 Antigen Rapid Test
Magnetic Bead Separation Modules
MAG and HEATMAG
POCT Fluorescent Immunoassay Analyzer
FIA Go
New
Gold Member
Fully Automated Cell Density/Viability Analyzer
BioProfile FAST CDV

Print article

Channels

Clinical Chemistry

view channel
Image: The 3D printed miniature ionizer is a key component of a mass spectrometer (Photo courtesy of MIT)

3D Printed Point-Of-Care Mass Spectrometer Outperforms State-Of-The-Art Models

Mass spectrometry is a precise technique for identifying the chemical components of a sample and has significant potential for monitoring chronic illness health states, such as measuring hormone levels... Read more

Hematology

view channel
Image: The CAPILLARYS 3 DBS devices have received U.S. FDA 510(k) clearance (Photo courtesy of Sebia)

Next Generation Instrument Screens for Hemoglobin Disorders in Newborns

Hemoglobinopathies, the most widespread inherited conditions globally, affect about 7% of the population as carriers, with 2.7% of newborns being born with these conditions. The spectrum of clinical manifestations... Read more

Immunology

view channel
Image: A false color scanning election micrograph of lung cancer cells grown in culture (Photo courtesy of Anne Weston)

AI Tool Precisely Matches Cancer Drugs to Patients Using Information from Each Tumor Cell

Current strategies for matching cancer patients with specific treatments often depend on bulk sequencing of tumor DNA and RNA, which provides an average profile from all cells within a tumor sample.... Read more

Microbiology

view channel
Image: Microscope image showing human colorectal cancer tumor with Fusobacterium nucleatum stained in a red-purple color (Photo courtesy of Fred Hutch Cancer Center)

Mouth Bacteria Test Could Predict Colon Cancer Progression

Colon cancer, a relatively common but challenging disease to diagnose, requires confirmation through a colonoscopy or surgery. Recently, there has been a worrying increase in colon cancer rates among younger... Read more

Pathology

view channel
Image: Fingertip blood sample collection on the Babson Handwarmer (Photo courtesy of Babson Diagnostics)

Unique Hand-Warming Technology Supports High-Quality Fingertip Blood Sample Collection

Warming the hand is an effective way to facilitate blood collection from a fingertip, yet off-the-shelf solutions often do not fulfill laboratory requirements. Now, a unique hand-warming technology has... Read more
Copyright © 2000-2024 Globetech Media. All rights reserved.